VICTRON Battery Management System Smart BMS 12/200
€211.09*
€266.95* (21% gespart)Delivery time: 3 - 5 Werktage
Product information "VICTRON Battery Management System Smart BMS 12/200"
The Smart BMS 12/200 is a complete battery management system for Victron intelligent lithium iron phosphate (LiFePO4) batteries. It has been specially developed for 12 V systems with a 12 V alternator, for example in vehicles and boats.
- Maximum continuous charge current: 100 A (with a 125 A fuse)
- Maximum charge current, SYSTEM+ terminal: 200 A
- Maximum discharge current, SYSTEM+ terminal: 200 A
- Peak discharge current: 400 A
- Input voltage to start charging: > 13 V
- Power consumption, operation without load: 16 mA (without load output and charge output current)
- Current draw, remote off: 5 mA (BMS functionality active)
- Load disconnect output: Normally high (Vbat - 0.1 V), source current limit: 10 mA (short-circuit proof), sink current: 0 A (output floating)
- Charge disconnect output: Normally high (Vbat - 0.1 V), source current limit: 10 mA (short-circuit proof), sink current: 0 A (output floating)
- Pre-alarm output: Normally floating, high (Vbat) in the event of an alarm, max. 1 A (not short-circuit proof)
- System on/off - Remote L and Remote H: Use the system's on/off switch modes: ON when terminals L and H are connected to each other, ON when terminal L is pulled to the negative battery terminal (V< 5V), EIN, wenn die Klemme H hoch ist (V > 3 V), OFF in all other states
- Operating temperature range: -40°C to +60°C
- Humidity, maximum / average: 100% / 95%
- Protection, electronics: IP65
- DC connection: M8
- DC connection battery negative: Faston receptacle, 6.3 mm
Battery Management System
The BMS is connected to 12.8 V Victron LiFePO4 batteries (LFP). Up to 5 batteries can be connected in parallel. Can be used as the system's on/off switch.
Alternator and battery protection
The input current is electronically limited to approximately 90% of the fuse rating. A 100 A fuse, for example, therefore limits the input current to approximately 90 A. Choosing the correct fuse will: protect the LFP battery from excessive charge current (important in the case of an LFP battery with low capacity); and protect the alternator from overload in the case of an LFP battery bank with high capacity (most 12 V alternators overheat and fail if operated at maximum output for longer than 5 minutes).
Starter battery protection
This function is similar to that of a Cyrix battery combiner or Argo FET battery isolator. Current can only flow to the LFP battery when the input voltage (= voltage at the starter battery) exceeds 13 V. In addition, current cannot flow back from the LFP battery to the starter battery, which prevents possible damage to the LFP battery through excessive discharge.
Load/battery charger output/input (power supply socket SYSTEM+)
Via this power supply socket, the LFP battery can either be charged or discharged (i.e. via a charger, an inverter or an inverter/charger) with a maximum continuous current of 200 A in both directions. It can also be used as a load output, so that DC loads can be connected directly to this terminal. The terminal is short-circuit proof with a peak discharge current of 400 A. The Smart BMS ensures that discharging of the battery is switched off when cell undervoltage is imminent. The Smart BMS enables charging via this terminal, but no charging algorithm can be applied internally.
Lithium-ion battery protection
Excessive input voltages and transients are regulated down to a safe level. The Smart BMS stops the charging process in the event of cell overvoltage or overtemperature. It has three outputs, similar to the smallBMS: Load disconnect output: The load output is normally high and becomes floating when the cell is at undervoltage (default 2.8 V/cell, adjustable on the battery between 2.6 V and 2.8 V per cell). Maximum current: 10 mA. The load output can be used to control the remote on/off input of a battery protector, an inverter, a DC/DC converter or other loads. The pre-alarm output can be used as a warning when the battery voltage is low, and it will trigger shortly before the load disconnect output is deactivated due to cell undervoltage. The pre-alarm output can be used to control a relay, an LED or a buzzer. It can be configured as a continuous or intermittent signal. The pre-alarm output is normally floating and becomes high when cell undervoltage is imminent (default 3.1 V/cell, adjustable on the battery between 2.85 V and 3.15 V per cell). Maximum current: 1 A (not short-circuit proof). The minimum delay between pre-alarm and load disconnection is 30 seconds. The "Charge disconnect" output is normally "High" and becomes floating when cell overvoltage or overtemperature is imminent. Maximum current: 10 mA. The "Charge disconnect" output is not suitable for operating an inductive load such as a relay coil. The "Charge disconnect" output can be used to control the remote on/off of a charger, a Cyrix-Li charge relay or a Cyrix-Li-ct battery combiner.
Remote on/off input
The remote on/off input controls charging via the alternator. In the switched-off state, charging via the alternator is disabled. However, the BMS functionality remains active, so all loads and chargers can continue to operate independently of the state of the remote input. If the system on/off switch is activated via VictronConnect, the BMS function is also deactivated. It consists of two terminals: Remote L and Remote H. A remote on/off switch or a relay contact can be connected between L and H. Alternatively, terminal H can be connected to a battery positive pole or L to a battery negative pole.
| Breite (cm): | 12 |
|---|---|
| Gewicht (kg): | 2 |
| Höhe (cm): | 6,5 |
| Tiefe (cm): | 34 |
| Marke: | VICTRON ENERGY |
| Schutzklasse: | 65 |

Victron Energy B.V.
De Paal 35
NL-1351 JG Almere











